Skip to the content
12345678910111213141516

74HC4052D

NexperiaExtended

-40℃~+125℃ 180MHz 2 27ns 2V~10V 38ns 4:1 5ns 80Ω SOIC-16 Analog Switches, Multiplexers ROHS

Part id
nexperia/74HC4052D
Category
Analog Switches, Multiplexers
Package
SOIC-16
Pins
16
In stock
62,170 at JLCPCB (C11350)

Overview

The 74HC4052D is an analog Switches, Multiplexer made by Nexperia in a SOIC-16 package with 16 pins. -40℃~+125℃ 180MHz 2 27ns 2V~10V 38ns 4:1 5ns 80Ω SOIC-16 Analog Switches, Multiplexers ROHS.

PCBKit's library has its KiCad symbol (4xxx:4052, from KiCad's library) and its footprint (Package_SO:SOIC-16_3.9x9.9mm_P1.27mm, from KiCad's library), ready for a KiCad board. 62,170 are in stock at JLCPCB (part C11350).

Symbol

1Y02Y23Y4Y35Y16Inh7VEE8VSS9B10A11X312X013X14X115X216VDD
4xxx:4052From KiCad's library

Footprint

12345678910111213141516
Package_SO:SOIC-16_3.9x9.9mm_P1.27mmFrom KiCad's library

From the datasheet

7
Supply, least
2 V · VCC - GND, recommended operating min · p. 6
Supply, most
10 V · VCC - GND, recommended operating max · p. 6
Supply, absolute maximum
11 V · VCC, absolute max; VEE = GND = 0 V · p. 6
Works from
-40 °C · ambient temperature min · p. 6
Works up to
125 °C · ambient temperature max · p. 6
Takes working
320 µA · VCC supply current max at 10 V, VEE = 0 V, inputs at rails, ambient -40 °C to +125 °C · p. 10
A pin gives at most
25 mA · switch current absolute max magnitude; -0.5 V < VSW < VCC + 0.5 V · p. 6

What it is and has

15
Analog switches
Dual 4-channel multiplexer/demultiplexer · p. 1
Analog input voltage range
-5 V to +5 V · p. 1
Power dissipation
CMOS low power dissipation · p. 1
Latch-up performance
Exceeds 100 mA per JESD 78 Class II Level B · p. 1
ON resistance
80 Ω typical at VCC - VEE = 4.5 V · p. 1
ON resistance
70 Ω typical at VCC - VEE = 6.0 V · p. 1
ON resistance
60 Ω typical at VCC - VEE = 9.0 V · p. 1
Logic level translation
5 V logic to ±5 V analog signals · p. 1
Switch sequencing
Typical break before make built-in · p. 1
Input levels
CMOS level · p. 1
ESD protection
HBM: ANSI/ESDA/JEDEC JS-001 class 2 exceeds 2000 V · p. 1
ESD protection
CDM: ANSI/ESDA/JEDEC JS-002 class C3 exceeds 1000 V · p. 1
JEDEC compliance
JESD8C (2.7 V to 3.6 V) · p. 1
JEDEC compliance
JESD7A (2.0 V to 6.0 V) · p. 1
Package
SO16; SOT109-1; 16 leads · p. 2

Specifications

82
ParameterConditionsAs printedPage
supply voltage VCCVEE = GND = 0 Vmin -0.5 · max 11 V6
input clamping current IIKVI < -0.5 V or VI > VCC + 0.5 V; maximum magnitude ±20 mAmax 20 mA6
switch clamping current ISKVSW < -0.5 V or VSW > VCC + 0.5 V; maximum magnitude ±20 mAmax 20 mA6
switch current ISW-0.5 V < VSW < VCC + 0.5 V; maximum magnitude ±25 mAmax 25 mA6
supply current IEEmaximum magnitude ±20 mAmax 20 mA6
supply current ICCmax 50 mA6
ground current IGNDmax -50 mA6
storage temperature Tstgmin -65 · max 150 °C6
power dissipation Pper switchmax 100 mW6
total power dissipation PtotSOT109-1 (SO16)max 500 mW6
supply voltage VCC74HC4052; VCC - GND; see Fig. 5 and Fig. 6min 2 · typ 5 · max 10 V6
supply voltage VCC74HC4052; VCC - VEE; see Fig. 5 and Fig. 6min 2 · typ 5 · max 10 V6
ambient temperature Tamb74HC4052min -40 · typ 25 · max 125 °C6
input transition rise and fall rate Δt/ΔV74HC4052; VCC = 2.0 Vmax 625 ns/V6
input transition rise and fall rate Δt/ΔV74HC4052; VCC = 4.5 Vtyp 1.67 · max 139 ns/V6
input transition rise and fall rate Δt/ΔV74HC4052; VCC = 6.0 Vmax 83 ns/V6
input transition rise and fall rate Δt/ΔV74HC4052; VCC = 10.0 Vmax 31 ns/V6
ON resistance (peak) RON(peak)74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VCC to VEE; VCC = 4.5 V; VEE = 0 V; ISW = 1000 uAtyp 100 · max 225 Ω7
ON resistance (peak) RON(peak)74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VCC to VEE; VCC = 6.0 V; VEE = 0 V; ISW = 1000 uAtyp 90 · max 200 Ω7
ON resistance (peak) RON(peak)74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VCC to VEE; VCC = 4.5 V; VEE = -4.5 V; ISW = 1000 uAtyp 70 · max 165 Ω7
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VEE; VCC = 2.0 V; VEE = 0 V; ISW = 100 uAtyp 150 Ω7
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VEE; VCC = 4.5 V; VEE = 0 V; ISW = 1000 uAtyp 80 · max 175 Ω7
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VEE; VCC = 6.0 V; VEE = 0 V; ISW = 1000 uAtyp 70 · max 150 Ω7
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VEE; VCC = 4.5 V; VEE = -4.5 V; ISW = 1000 uAtyp 60 · max 130 Ω7
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VCC; VCC = 2.0 V; VEE = 0 V; ISW = 100 uAtyp 150 Ω7
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VCC; VCC = 4.5 V; VEE = 0 V; ISW = 1000 uAtyp 90 · max 200 Ω7
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VCC; VCC = 6.0 V; VEE = 0 V; ISW = 1000 uAtyp 80 · max 175 Ω7
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VCC; VCC = 4.5 V; VEE = -4.5 V; ISW = 1000 uAtyp 65 · max 150 Ω7
ON resistance mismatch between channels ΔRON74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VCC to VEE; VCC = 4.5 V; VEE = 0 Vtyp 9 Ω7
ON resistance mismatch between channels ΔRON74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VCC to VEE; VCC = 6.0 V; VEE = 0 Vtyp 8 Ω7
ON resistance mismatch between channels ΔRON74HC4052; Tamb = -40 °C to +85 °C; VI = VIH or VIL; Vis = VCC to VEE; VCC = 4.5 V; VEE = -4.5 Vtyp 6 Ω7
ON resistance (peak) RON(peak)74HC4052; Tamb = -40 °C to +125 °C; VI = VIH or VIL; Vis = VCC to VEE; VCC = 4.5 V; VEE = 0 V; ISW = 1000 uAmax 270 Ω8
ON resistance (peak) RON(peak)74HC4052; Tamb = -40 °C to +125 °C; VI = VIH or VIL; Vis = VCC to VEE; VCC = 6.0 V; VEE = 0 V; ISW = 1000 uAmax 240 Ω8
ON resistance (peak) RON(peak)74HC4052; Tamb = -40 °C to +125 °C; VI = VIH or VIL; Vis = VCC to VEE; VCC = 4.5 V; VEE = -4.5 V; ISW = 1000 uAmax 195 Ω8
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +125 °C; VI = VIH or VIL; Vis = VEE; VCC = 4.5 V; VEE = 0 V; ISW = 1000 uAmax 210 Ω8
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +125 °C; VI = VIH or VIL; Vis = VEE; VCC = 6.0 V; VEE = 0 V; ISW = 1000 uAmax 180 Ω8
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +125 °C; VI = VIH or VIL; Vis = VEE; VCC = 4.5 V; VEE = -4.5 V; ISW = 1000 uAmax 160 Ω8
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +125 °C; VI = VIH or VIL; Vis = VCC; VCC = 4.5 V; VEE = 0 V; ISW = 1000 uAmax 240 Ω8
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +125 °C; VI = VIH or VIL; Vis = VCC; VCC = 6.0 V; VEE = 0 V; ISW = 1000 uAmax 210 Ω8
ON resistance (rail) RON(rail)74HC4052; Tamb = -40 °C to +125 °C; VI = VIH or VIL; Vis = VCC; VCC = 4.5 V; VEE = -4.5 V; ISW = 1000 uAmax 180 Ω8
HIGH-level input voltage VIHTamb = -40 °C to +85 °C; VCC = 2.0 Vmin 1.5 · typ 1.2 V9
HIGH-level input voltage VIHTamb = -40 °C to +85 °C; VCC = 4.5 Vmin 3.15 · typ 2.4 V9
HIGH-level input voltage VIHTamb = -40 °C to +85 °C; VCC = 6.0 Vmin 4.2 · typ 3.2 V9
HIGH-level input voltage VIHTamb = -40 °C to +85 °C; VCC = 9.0 Vmin 6.3 · typ 4.7 V9
LOW-level input voltage VILTamb = -40 °C to +85 °C; VCC = 2.0 Vtyp 0.8 · max 0.5 V9
LOW-level input voltage VILTamb = -40 °C to +85 °C; VCC = 4.5 Vtyp 2.1 · max 1.35 V9
LOW-level input voltage VILTamb = -40 °C to +85 °C; VCC = 6.0 Vtyp 2.8 · max 1.8 V9
LOW-level input voltage VILTamb = -40 °C to +85 °C; VCC = 9.0 Vtyp 4.3 · max 2.7 V9
input leakage current IITamb = -40 °C to +85 °C; VEE = 0 V; VI = VCC or GND; VCC = 6.0 V; maximum magnitude ±1.0 uAmax 1 uA9
input leakage current IITamb = -40 °C to +85 °C; VEE = 0 V; VI = VCC or GND; VCC = 10.0 V; maximum magnitude ±2.0 uAmax 2 uA9
OFF-state leakage current IS(OFF)Tamb = -40 °C to +85 °C; VCC = 10.0 V; VEE = 0 V; VI = VIH or VIL; |VSW| = VCC - VEE; per channel; see Fig. 9; maximum magnitude ±1.0 uAmax 1 uA9
OFF-state leakage current IS(OFF)Tamb = -40 °C to +85 °C; VCC = 10.0 V; VEE = 0 V; VI = VIH or VIL; |VSW| = VCC - VEE; all channels; see Fig. 9; maximum magnitude ±2.0 uAmax 2 uA9
ON-state leakage current IS(ON)Tamb = -40 °C to +85 °C; VCC = 10.0 V; VEE = 0 V; VI = VIH or VIL; |VSW| = VCC - VEE; see Fig. 10; maximum magnitude ±2.0 uAmax 2 uA9
supply current ICCTamb = -40 °C to +85 °C; VEE = 0 V; VI = VCC or GND; Vis = VEE or VCC; Vos = VCC or VEE; VCC = 6.0 Vmax 80 uA9
supply current ICCTamb = -40 °C to +85 °C; VEE = 0 V; VI = VCC or GND; Vis = VEE or VCC; Vos = VCC or VEE; VCC = 10.0 Vmax 160 uA9
input capacitance CITamb = -40 °C to +85 °C; typical at Tamb = 25 °Ctyp 3.5 pF9
switch capacitance CswTamb = -40 °C to +85 °C; independent pins nYn; typical at Tamb = 25 °Ctyp 5 pF9
switch capacitance CswTamb = -40 °C to +85 °C; common pins nZ; typical at Tamb = 25 °Ctyp 12 pF9
HIGH-level input voltage VIHTamb = -40 °C to +125 °C; VCC = 2.0 Vmin 1.5 V9
HIGH-level input voltage VIHTamb = -40 °C to +125 °C; VCC = 4.5 Vmin 3.15 V9
HIGH-level input voltage VIHTamb = -40 °C to +125 °C; VCC = 6.0 Vmin 4.2 V9
HIGH-level input voltage VIHTamb = -40 °C to +125 °C; VCC = 9.0 Vmin 6.3 V9
LOW-level input voltage VILTamb = -40 °C to +125 °C; VCC = 2.0 Vmax 0.5 V9
LOW-level input voltage VILTamb = -40 °C to +125 °C; VCC = 4.5 Vmax 1.35 V9
LOW-level input voltage VILTamb = -40 °C to +125 °C; VCC = 6.0 Vmax 1.8 V9
LOW-level input voltage VILTamb = -40 °C to +125 °C; VCC = 9.0 Vmax 2.7 V9
input leakage current IITamb = -40 °C to +125 °C; VEE = 0 V; VI = VCC or GND; VCC = 6.0 V; maximum magnitude ±1.0 uAmax 1 uA9
input leakage current IITamb = -40 °C to +125 °C; VEE = 0 V; VI = VCC or GND; VCC = 10.0 V; maximum magnitude ±2.0 uAmax 2 uA9
OFF-state leakage current IS(OFF)Tamb = -40 °C to +125 °C; VCC = 10.0 V; VEE = 0 V; VI = VIH or VIL; |VSW| = VCC - VEE; per channel; see Fig. 9; maximum magnitude ±1.0 uAmax 1 uA9
OFF-state leakage current IS(OFF)Tamb = -40 °C to +125 °C; VCC = 10.0 V; VEE = 0 V; VI = VIH or VIL; |VSW| = VCC - VEE; all channels; see Fig. 9; maximum magnitude ±2.0 uAmax 2 uA9
ON-state leakage current IS(ON)Tamb = -40 °C to +125 °C; VCC = 10.0 V; VEE = 0 V; VI = VIH or VIL; |VSW| = VCC - VEE; see Fig. 10; maximum magnitude ±2.0 uAmax 2 uA10
supply current ICCTamb = -40 °C to +125 °C; VEE = 0 V; VI = VCC or GND; Vis = VEE or VCC; Vos = VCC or VEE; VCC = 6.0 Vmax 160 uA10
supply current ICCTamb = -40 °C to +125 °C; VEE = 0 V; VI = VCC or GND; Vis = VEE or VCC; Vos = VCC or VEE; VCC = 10.0 Vmax 320 uA10
propagation delay tpdTamb = -40 °C to +85 °C; GND = 0 V; tr = tf = 6 ns; CL = 50 pF; Vis to Vos; RL = ∞ Ω; VCC = 2.0 V; VEE = 0 V; see Fig. 11typ 14 · max 75 ns11
propagation delay tpdTamb = -40 °C to +85 °C; GND = 0 V; tr = tf = 6 ns; CL = 50 pF; Vis to Vos; RL = ∞ Ω; VCC = 4.5 V; VEE = 0 V; see Fig. 11typ 5 · max 15 ns11
propagation delay tpdTamb = -40 °C to +85 °C; GND = 0 V; tr = tf = 6 ns; CL = 50 pF; Vis to Vos; RL = ∞ Ω; VCC = 6.0 V; VEE = 0 V; see Fig. 11typ 4 · max 13 ns11
propagation delay tpdTamb = -40 °C to +85 °C; GND = 0 V; tr = tf = 6 ns; CL = 50 pF; Vis to Vos; RL = ∞ Ω; VCC = 4.5 V; VEE = -4.5 V; see Fig. 11typ 4 · max 10 ns11
turn-on time tonTamb = -40 °C to +85 °C; GND = 0 V; tr = tf = 6 ns; CL = 50 pF; E, Sn to Vos; RL = ∞ Ω; VCC = 2.0 V; VEE = 0 V; see Fig. 12typ 105 · max 405 ns11
turn-on time tonTamb = -40 °C to +85 °C; GND = 0 V; tr = tf = 6 ns; CL = 50 pF; E, Sn to Vos; RL = ∞ Ω; VCC = 4.5 V; VEE = 0 V; see Fig. 12typ 38 · max 81 ns11
turn-on time tonTamb = -40 °C to +85 °C; GND = 0 V; tr = tf = 6 ns; CL = 15 pF; E, Sn to Vos; RL = ∞ Ω; VCC = 5.0 V; VEE = 0 V; see Fig. 12typ 28 ns11
turn-on time tonTamb = -40 °C to +85 °C; GND = 0 V; tr = tf = 6 ns; CL = 50 pF; E, Sn to Vos; RL = ∞ Ω; VCC = 6.0 V; VEE = 0 V; see Fig. 12typ 30 · max 69 ns11
turn-on time tonTamb = -40 °C to +85 °C; GND = 0 V; tr = tf = 6 ns; CL = 50 pF; E, Sn to Vos; RL = ∞ Ω; VCC = 4.5 V; VEE = -4.5 V; see Fig. 12typ 26 · max 58 ns11

Pins, by the datasheet

16
1 2Y0
Independent input or output. · p. 5
2 2Y2
Independent input or output. · p. 5
3 2Z
Common input or output. · p. 5
4 2Y3
Independent input or output. · p. 5
5 2Y1
Independent input or output. · p. 5
6 E
Enable input (active LOW). · p. 5
7 VEE
Negative supply voltage. · p. 5
8 GND
Ground (0 V). · p. 5
9 S1
Select logic input. · p. 5
10 S0
Select logic input. · p. 5
11 1Y3
Independent input or output. · p. 5
12 1Y0
Independent input or output. · p. 5
13 1Z
Common input or output. · p. 5
14 1Y1
Independent input or output. · p. 5
15 1Y2
Independent input or output. · p. 5
16 VCC
Positive supply voltage. · p. 5

Ordering codes, by the datasheet

4
74HC4052D
SO16 · SOT109-1; -40 °C to +125 °C · p. 2
74HC4052PW
TSSOP16 · SOT403-1; -40 °C to +125 °C · p. 2
74HC4052BQ
DHVQFN16 · SOT763-1; -40 °C to +125 °C · p. 2
74HC4052BZ
DHXQFN16 · SOT8016-1; -40 °C to +125 °C · p. 2

Parts like it

8

Questions

Is there a KiCad symbol and footprint for the 74HC4052D?

Yes. The symbol is 4xxx:4052 and the footprint Package_SO:SOIC-16_3.9x9.9mm_P1.27mm, both drawn on this page. PCBKit places them on a board for you when you design with it.

What package is the 74HC4052D?

SOIC-16, with 16 pins. Its footprint is drawn on this page.

Where is the 74HC4052D datasheet?

Nexperia publishes it: the Datasheet link on this page opens it.

Where can I order the 74HC4052D?

JLCPCB lists it as part C11350, with 62,170 in stock; the sellers' links on this page open their listings.

What can replace the 74HC4052D?

Parts like it in the library: the CD4051BM/TR by HGSEMI, the CD4052BM96 by Texas Instruments, the HEF4052BT by Nexperia and the CD4051BM96 by Texas Instruments. Check their datasheets: a part that fits the footprint may still differ in its ratings.